In this week's article, I'm presenting a high-level overview of the Power i, System i, and the iSeries system attention indicator light, which is activated when the system detects a problem. While it may be mundane to concentrate on how the system alerts you when something goes wrong, this information can come in handy when that little amber light blinks on and you're not sure what to do.

Where Is the System Attention Light?

You can generally find the system attention indicator light (SA light) on the System Unit panel near the green power light, although the location varies by model. The indicator is usually a square(ish) amber or yellow light with a black exclamation point (!, the bang character) painted on its plastic surface. In addition to the system attention light, you may also need to check the Function/Data Display LED on the panel for system error codes that can help explain what problems are occurring on your system.

What Causes the SA Light To Come On?

The indicator light usually comes on when the system thinks that a problem exists. In my experience, the light turns on following these system events:

  • A component failure, such as when a communications or network card fails or when a raided disk drive crashes.
  • A power supply failure, such as when a redundant power supply dies.
  • After an unplanned power outage, when the system detects that power had been lost. The indicator may also come on after planned power outages, such as when you unplug an external component or after you power down and move a System i from one location to another.
  • When cache batteries fail.
  • When a "white error" shows up in the QSYSOPR message queue.
  • In some i5/OS installs, an error in the license code will cause your system attention indicator to light up. If that happens, it's been reported that installing the most recent cumulative PTFs can help straighten out problems with the SA light.

You may find additional system reference codes on the Function/Display Data LED. These codes can help you or your service provider determine the source of the problem. The Function/Display Data LED is also located on the system panel.

What's a White Error?

A white error is a critical system message that appears in white text in the QSYSOPR message queue (as opposed to other QSYSOPR messages, which appear in green text, or the standard text field color of your 5250 display). White errors denote more serious system-related problems that IBM wants you to deal with right away. A white error is usually preceded in QSYSOPR by one of the following CPF messages.

CPPEA13  - *Attention*  Contact your hardware service provider
CPPEA14  - *Attention*  Contact your hardware service provider

Although these messages look the same, they have different system severity levels. The CPPEA13 message is a severity 70 error, while the CPPEA14 is a severity 99 error. I'm not sure why IBM needs duplicate message IDs with different severity levels, but if some IBMer reading this column has an explanation, I'll print their reply in a future column.

What's the Drill for Turning Off the SA Light?

Before turning off the SA light, it's vitally important to understand why it was turned on in the first place. A good rule of thumb is to never turn off the attention light before your problem is solved. As mentioned before, the problem might be easy to fix (the power went out and now it's back on again) or more difficult (replacing a failed disk drive). If it's serious enough, you may need to call IBM or a third-party contractor to take care of the issue. In most cases, they'll turn off the indicator after fixing the problem, but sometimes they'll forget and you'll want to do it yourself.

How Can I Turn Off the Light?

After you've received the all clear on your problem, there are two ways to turn off the SA light. You can turn it off from either the green screen or inside your system's Hardware Management Console (HMC).

To turn it off from the green screen, you'll need to clear the error either in i5/OS' Dedicated Service Tools (DST) or System Service Tools (SST) function. For this example, I'll show you how to turn it off in SST, but the same concepts and options apply when turning it off in DST.

You can enter SST by running the following Start System Service Tools (STRSST) command from a command line.

STRSST

The system will ask you for an authorized SST user ID and password. After you use these to sign on, it will display the System Service Tools menu. Take the following options off this menu.

  1. Take option 1, Start a Service Tool. This brings up the Start a Service Tool menu.
  2. Take option 7, Hardware Service Manager.
  3. On the Hardware Service Manager menu, take option 6, Work with Service Action Log.
  4. A Select Timeframe screen will open, and you will be asked to enter the timeframe in which the error occurred. By default, the screen will select all the errors that occurred in the last 24 hours. If you want to change the default timeframe, enter new From and To dates and times for the time period that you want to see errors for. Once you press ENTER, the Service Action Log Report screen will open.
  5. The Service Action Log Report screen displays all hardware errors that require help from a service rep. If your problem is solved and the entry is still open in the log, you can use "Option 8=Close a NEW Entry" to change the entry status to CLOSED. If all entries are CLOSED, this may be enough to turn off the system attention light. If the light is still on, you should see a literal at the bottom of the screen that reads "F6=Acknowledge All Errors." If that literal appears and you press the F6 key, that will deactivate the partition's system attention indicator.

If you prefer to turn off the system attention indicator from the Hardware Management Console (HMC), you can use the following instructions.

  1. Inside your HMC, open the Service Applications folder.
  2. Under Service Applications, open the Service Focal Point node. Service Focal Point is an HMC application that is designed for diagnosing and repairing problems in the system.
  3. In the Service Focal Point panel on the right-hand side of the screen, select Service Utilities.
  4. In the Service Utilities window, click on Selected→System Attention LED from the window's menu bar.
  5. In the System Attention LED window that appears, highlight the partition where the SA light is active and select Action, Deactivate System Attention LED from the menu bar. Several confirmation messages will appear on the screen before the system will turn the light off.

Finally, it's important to note that if you're trying to turn off the System Attention LED from either environment (green screen SST/DST or the HMC) and the light remains on, you should call IBM or your service provider for more information.

About Our Testing Environment

Configurations described in this article were tested on two i5 550 boxes running i5/OS V5R4 and V5R3. If a command is present in earlier versions of the i5/OS or OS/400 operating systems, you may notice some variations in the pre-V5R3 copies of these commands. These differences may be due to command improvements that have occurred from release to release.




                     Post this story to del.icio.us
               Post this story to Digg
    Post this story to Slashdot


Sponsored By
COMMON

COMMON Focus 2008, our annual workshop conference,
returns with three days of intense, focused education.

October 5 - 8, 2008
San Francisco, California

COMMON Focus 2008 will be a smaller, more intimate event than a traditional
COMMON conference with a limited number of attendees--allowing attendees
more one-on-one interaction with the speakers and each other.

Building on the success of the inaugural COMMON Focus conference last year,
in-depth, all-day educational workshops will again be offered--both in lab and
lecture-style formats--in a wide range of topic areas. Attendees can attend
only one workshop per day, providing attendees the opportunity to focus
their educational needs on a specific topic each day.

COMMON Focus 2008 will kickoff on the evening of Sunday, October 5th,
with a Welcome Reception, where attendees and workshop instructors
can meet and network. A continental breakfast and lunch will be provided each day,
along with several breaks, giving attendees time to interact with each other.

COMMON Focus 2008 will also have a tabletop-style exhibition area, featuring
a limited number of exhibitors. Attendees will be able to view and
get hands-on demonstration on the latest i-related solutions available to them.

This innovative educational conference promises to be three days of intense learning.
It is an educational opportunity that you don't want to miss.

Learn more at
www.common.org/focus


Senior Technical Editor: Ted Holt
Technical Editor: Joe Hertvik
Contributing Technical Editors: Edwin Earley, Brian Kelly, Michael Sansoterra
Publisher and Advertising Director: Jenny Thomas
Advertising Sales Representative: Kim Reed
Contact the Editors: To contact anyone on the IT Jungle Team
Go to our contacts page and send us a message.

Sponsored Links

COMMON:  Join us at the Focus 2008 workshop conference, October 5 - 8, in San Francisco, California
Profound Logic Software:  Web-enable in less than a day with Genie
Vision Solutions:  System i Management Tips Blog - Free i5/OS Tips Each Week!


 

IT Jungle Store Top Book Picks

Easy Steps to Internet Programming for AS/400, iSeries, and System i: List Price, $49.95
Getting Started with PHP for i5/OS: List Price, $59.95
The System i RPG & RPG IV Tutorial and Lab Exercises: List Price, $59.95
The System i Pocket RPG & RPG IV Guide: List Price, $69.95
The iSeries Pocket Database Guide: List Price, $59.00
The iSeries Pocket Developers' Guide: List Price, $59.00
The iSeries Pocket SQL Guide: List Price, $59.00
The iSeries Pocket Query Guide: List Price, $49.00
The iSeries Pocket WebFacing Primer: List Price, $39.00
Migrating to WebSphere Express for iSeries: List Price, $49.00
iSeries Express Web Implementer's Guide: List Price, $59.00
Getting Started with WebSphere Development Studio for iSeries: List Price, $79.95
Getting Started With WebSphere Development Studio Client for iSeries: List Price, $89.00
Getting Started with WebSphere Express for iSeries: List Price, $49.00
WebFacing Application Design and Development Guide: List Price, $55.00
Can the AS/400 Survive IBM?: List Price, $49.00
The All-Everything Machine: List Price, $29.95
Chip Wars: List Price, $29.95


 
The Four Hundred
The Power Systems M15 and M25 Versus Their Predecessors

Forget About Platforms, Let's Talk About Jobs

Zend Taps System i-PHP Guru, Pushes the i Platform

As I See It: Citizen CEO

Imtech Buys Reseller Real Solutions for U.K. Expansion

The Linux Beacon
How's Red Hat Enterprise Linux 5 Doing?

AMD Finishes Off Quad Cores with Budapest Opterons

Forget About Platforms, Let's Talk About Jobs

As I See It: Citizen CEO

Looks Like Unisys Is Reselling Sun's X4600 Opteron Boxes

Four Hundred Stuff
Bank's Approach to Biometric Authentication a 'Valid' One

Programmer Conveniences Added to BCD's WebSmart ILE

ASNA Brings RPG to .NET Migration Software to Latest Windows IDE

Safestone Re-emerges with New Corporate Identity, i OS Security Tools

NetManage and HiT Software Partner for Structured Data

Big Iron
The Back and Forth of the PSI-IBM Lawsuit

Top Mainframe Stories From Around the Web

Chats, Webinars, Seminars, Shows, and Other Happenings

System i PTF Guide
June 7, 2008: Volume 10, Number 23

May 31, 2008: Volume 10, Number 22

May 24, 2008: Volume 10, Number 21

May 17, 2008: Volume 10, Number 20

May 10, 2008: Volume 10, Number 19

May 3, 2008: Volume 10, Number 18

The Windows Observer
Microsoft Kicks Off TechEd 2008 with Gates and Previews

Dynamics AX 2009 ERP Suite Comes to Market

U.S. Drags Down Server Sales in Q1, But Weak Dollar Helps

Servers, Storage, Laptops and Weak Dollars Buoy Dell in Q1

Server Branding 101: Big Name, Big Game?

The Unix Guardian
AMD Finishes Off Quad Cores with Budapest Opterons

U.S. Drags Down Server Sales in Q1, But Weak Dollar Helps

Looks Like Unisys Is Reselling Sun's X4600 Opteron Boxes

Themis Partners with Sun to Make Sparc T2 Blade Server

Server Branding 101: Big Name, Big Game?

Four Hundred Monitor
Four Hundred Monitor's
Full iSeries Events Calendar

THIS ISSUE SPONSORED BY:

Help/Systems
Group8 Security
COMMON


Printer Friendly Version


TABLE OF CONTENTS
Keeping 5250 Alive

Seeking Advice on REXX

Admin Alert: All About the System i Attention Light

Four Hundred Guru

BACK ISSUES

From the IT Jungle Forums
Capture Sort File and Copy to Database File

SNMP Traps on i5OS

Java Messages

Copying recs from a subfile to a file and keeping highlights

Imbedded SQL

CPYFRMSTMF problem





 
Subscription Information:
You can unsubscribe, change your email address, or sign up for any of IT Jungle's free e-newsletters through our Web site at http://www.itjungle.com/sub/subscribe.html.

Copyright © 1996-2008 Guild Companies, Inc. All Rights Reserved.
Guild Companies, Inc., 50 Park Terrace East, Suite 8F, New York, NY 10034

Privacy Statement