EPA Says American Data Centers Can Cut Power Use Dramatically

Published: August 9, 2007

by Timothy Prickett Morgan

As instructed to do by the U.S. Congress, the Environmental Protection Agency has made its formal report to lawmakers regarding the energy consumption of servers, storage, and other gear at the data centers in America. The EPA has been instrumental in getting Americans to use energy-efficient appliances and in getting manufacturers to build them through its Energy Star program, and it is hoping to do the same in data centers.

Back in December 2006, Congress passed a law and President Bush signed it requiring the EPA to report back to Congress within 180 days with an analysis the use of servers and related infrastructure and their power consumption in the United States. EPA was also instructed to forecast the impact of using energy-efficient technologies in data centers to reduce energy demands and to make recommendations for the formation of incentives and voluntary programs for the IT industry and consumers that could spur the use of energy-efficient computer designs. This is exactly what the EPA's Energy Star program did for appliances and consumer electronics.

Not all servers are in data centers, so to get a sense of the scope of the problem, the EPA had to get a grip on how much power servers were consuming and then, for those in data centers, how much juice these centers burned as well. According to the report issued last Friday, America's server consumed about 61 billion kilowatt-hours of juice in 2006, about 1.5 percent of total electricity consumption in the country and representing about $4.5 billion in costs. Servers ate about as much electricity as all of the color televisions in the country, and about the same amount of power as 5.8 million typical households. This is about twice the amount of electricity that servers and data centers consumed in 2000.

The EPA said in its report to Congress that under current trends--meaning no one does much about energy efficiency--by 2011 electricity usage by servers and data centers could nearly double again, to more than 100 billion kilowatts and $7.4 billion in annual electricity bills. Perhaps more significantly, these machines put a peak load of 7 gigawatts on the North American electric grid in 2006, and this could grow to 12 gigawatts by 2011. That was 15 baseload power plants in 2006, and would require another 10 plants to cover the peak load.

Looking out ahead, EPA put together a few scenarios to show how we might cope with this increase in power demand for servers. These are shown in the graph below:


If you just plot out current electricity usage trends in data centers and among free-standing departmental servers, you end up with demand for over 120 billion kilowatt-hours of juice by 2011. Using some of the current efficiency method available today--server consolidation enabled by virtualization, energy efficient multicore processors, and so forth--still puts the country at above 100 billion kilowatt-hours by 2011. Under an "improved operation" scenario, which means doing very little capital investment but changing the way servers are used, the EPA reckons that the country could make a big, quick dent in energy usage, but then eventually get pulled up by the server sprawl curve and track parallel with the historical electricity usage curve to hit around 85 billion kilowatt-hours of annual electricity consumption four years from now. This scenario means doing server consolidation, eliminating unused boxes, using some energy efficient designs, turning on power management features in the hardware and software, getting disk arrays that use less energy, and rejiggering data centers so airflow is more efficient.

In the "best practice" scenario that EPA cooked up, if every data center in the country and every server was designed and deployed with the most energy-efficient technologies available today, we might actually get on a declining curve, compressing electricity usage down to 45 billion kilowatt-hours. This scenario means doing a moderate level of server consolidation, aggressively adopting energy efficient servers, and doing a moderate level of storage consolidation; it also implies improving transformers, power supplies, chillers, fans, and pumps in the data center.

And in the "state-of-the-art" scenario, which is the absolute best case scenario, servers and storage are aggressively consolidated, and power management spans the entire data centers, from applications right up to the ceiling. It also means direct liquid cooling of servers and storage, and radical changes in the way that power is distributed in data centers.

With the federal government consuming about one-tenth of the electricity used by servers in the United States, the EPA is recommending first and foremost that Uncle Sam lead by example. (That's easy to say, but hard to do. What Congressional leader is going to recommend the wholesale upgrading of the government's data centers? Who is going to pay for it?) The EPA is also recommending the standardization of energy performance metrics for data centers, but acknowledges that given the diversity of electronics and configurations, this seems a tough task. The government agency is asking that chief executive officers conduct an energy efficiency assessment under the Department of Energy's Save Energy Now program, which would create tools to help data center managers deploy best practices and measure their progress toward better efficiency. And, not surprisingly, the EPA wants to investigate the possibility of getting Energy Star ratings on the equipment inside data centers. This latter idea seems like a no-brainer, but you can bet that IT equipment vendors are going to be of two minds on this one. They like to brag about bandwidth and throughput for their gear, but they don't necessarily like to admit that the performance of their gear always comes at a cost.


RELATED STORIES

IBM Sees Green in Going Green in Data Centers

How To Build a Green Data Center

Uncle Sam Pushes Energy Star Ratings for Servers

Power Company Gives Rebates on Energy-Efficient Servers

AMD's Green Grid Project to Educate IT on Power Issues

The Balance of Server Powers

Lean, Mean Green Machines



                     Post this story to del.icio.us
               Post this story to Digg
    Post this story to Slashdot


Sponsored By
VIBRANT TECHNOLOGIES

HP, IBM and Sun Server Deals via RSS

                                                  · Subscribe to our Specials via RSS
                                                  · Up to 80% off manufacturer's list price
                                                  · Multi-million dollar inventory

We Buy & Sell new and remarketed servers,
upgrades, peripherals and parts.

HP Proliant, IBM xSeries, IBM pSeries, RS6000,
HP Integrity, Sun Microsystems, Cisco, more…
888-443-8606

View or Subscribe to:
Special Offers on Servers and Upgrades


Editor: Timothy Prickett Morgan
Contributing Editors: Dan Burger, Joe Hertvik,
Shannon O'Donnell, Timothy Prickett Morgan
Publisher and Advertising Director: Jenny Thomas
Advertising Sales Representative: Kim Reed
Contact the Editors: To contact anyone on the IT Jungle Team
Go to our contacts page and send us a message.

Sponsored Links

Vibrant Technologies:  Quality Used Servers, Storage & Networking Hardware at up to 80% off new
World Data Products:  FREE 84-page Unix/Midrange Server Spec Book
COMMON:  Join us at the Annual 2008 conference, March 30 - April 3, in Nashville, Tennessee


The Four Hundred
System i Announcement Wrap Up

IBM Upgrades System i Storage with SAS Drives

Mainframe Vendor BluePhoenix Ready to Purchase ASNA

As I See It: Policeware

The Linux Beacon
AMD Gooses Dual-Core Opteron Speeds, Cuts Prices

IBM Takes Its Own Server Consolidation Medicine

NEC Brings Linux, Windows Clustering Software to North America

As I See It: Policeware

Four Hundred Stuff
IBM Prepares to Launch DB2 Web Query for System i

IBM Details MySQL on System i Offering

CCSS Adds Predictive Capability to System Monitoring Tool

VAI Automates Service Calls, Tightens Inventory Control

Big Iron
IBM Takes Its Own Server Consolidation Medicine

Top Mainframe Stories From Around the Web

Chats, Webinars, Seminars, Shows, and Other Happenings

Four Hundred Guru
Use WDSc to Develop XSL Transformations

Have Your Cake and Eat It, Too

Admin Alert: Getting Around System i Default Passwords, Part 2

System i PTF Guide
August 4, 2007: Volume 9, Number 31

July 28, 2007: Volume 9, Number 30

July 21, 2007: Volume 9, Number 29

July 14, 2007: Volume 9, Number 28

July 7, 2007: Volume 9, Number 27

June 30, 2007: Volume 9, Number 26

The Windows Observer
AMD Gooses Dual-Core Opteron Speeds, Cuts Prices

IIS Gains More Web Server Market Share, Says Netcraft

NEC Brings Linux, Windows Clustering Software to North America

Unisys First Up with TPC-E Benchmark Test

Four Hundred Monitor
Four Hundred Monitor's
Full iSeries Events Calendar

THIS ISSUE SPONSORED BY:

MKS
Centrify
Roaring Penguin
Arkeia
Vibrant Technologies



TABLE OF CONTENTS
Sun Polishes Up Sparc T2 Multithreaded Chips

AMD Gooses Dual-Core Opteron Speeds, Cuts Prices

Sun Creates Virtual Tape Library from Thumper Server

As I See It: Policeware

But Wait, There's More:


EPA Says American Data Centers Can Cut Power Use Dramatically . . . Sun to Cut More Jobs, Book Restructuring Charges . . . Server Makers Dominate Tape Market, Says IDC . . . Avocent Debuts Entry Remote Management Appliance for SMBs . . . 'What Gets Measured Gets Managed' Applied to ERP . . . IBM Unveils Virtual E-Mail Security Appliance . . .

The Unix Guardian

BACK ISSUES





 
Subscription Information:
You can unsubscribe, change your email address, or sign up for any of IT Jungle's free e-newsletters through our Web site at http://www.itjungle.com/sub/subscribe.html.

Copyright © 1996-2008 Guild Companies, Inc. All Rights Reserved.
Guild Companies, Inc., 50 Park Terrace East, Suite 8F, New York, NY 10034

Privacy Statement