• The Four Hundred
  • Subscribe
  • Media Kit
  • Contributors
  • About Us
  • Contact
Menu
  • The Four Hundred
  • Subscribe
  • Media Kit
  • Contributors
  • About Us
  • Contact
  • Just When Do IBM i PTFs Get Applied, Anyway?

    March 28, 2012 Hey, Joe

    Our management has our operators apply cumulative PTFs (CUME) with no regard to when the system will be IPLed. They load the CUME, and the system may not be IPLed until a few weeks later. The managers believe that no PTFs are applied until after the IPL. I think that some PTFs are applied immediately, while others wait for the IPL. What’s the real story on how PTFs are applied?

    –Dave

    This is an interesting question. For most shops, PTFs aren’t usually applied until you IPL the system. But in some situations, eligible CUME PTFs can be applied immediately, depending on how your IBM i partition is configured. Here’s what I know.

    CUME PTFs are installed by using option 8 (Install Temporary Fix Package) off the Program Temporary Fix menu (GO PTF). What many shops don’t realize is that there are options for setting up an option 8 install that designate whether immediate PTFs are actually applied immediately (without an IPL) or whether they are loaded and marked delayed to be applied during an IPL. While it’s not relevant to your question, these options are also used for installing PTFs through the Install Program Temporary Fix (INSPTF) command or through GO PTF, option 7 (Install a program temporary fix from a list).

    This setting is called the PTF install type (PTFINSTYP) service attribute. By default, PTFINSTYP is set to mark all loaded PTFs (including immediate PTFs) to be installed during the next IPL. But your default PTFINSTYP attribute can be changed or it can be overridden during an option 7 or option 8 PTF install or inside the INSPTF command.

    You can check your PTFINSTYP attribute by running the Change Service Attributes command (CHGSRVA) and pressing F4. Look at the PTF install type (PTFINSTYP) parameter. The value listed on the CHGSRVA screen will be the default PTF application value for your GO PTF, option 7 or 8 screens and for the INSPTF command. The CHGSRVA screen looks like this.

    The default PTFINSTYP service attribute can be set to one of the following four values.

    1. *DLYIPL = All PTFs, including immediate PTFs, are marked for delayed application (apply during an IPL), and an IPL is performed after the option or command are completed. This is the default setting for the PTFINSTYP service attribute.
    2. *DLYALL = All PTFs are marked for delayed application and an IPL is NOT performed after the command or option is entered.
    3. *IMMONLY = All immediate PTFs in the CUME are immediately applied. Delayed PTFs are not marked for delayed application. There will be no system IPL after the command completes. IBM doesn’t recommend that you use *IMMONLY for cumulative PTF packages because you could wind up applying PTFs to products that are in use.
    4. *IMMDLY = All immediate PTFs are immediately applied and delayed PTFs are marked for delayed application during the next IPL. Again, IBM doesn’t recommend using this setting because you could apply PTFs to products in use.

    My guess is that your PTFINSTYP service attribute is set to mark everything for delayed application during an IPL (*DLYIPL or *DLYALL). But the CHGSRVA command can tell you what your system is actually set up for.

    Also keep in mind that these settings can be overridden in an option 8 load by whoever is applying the PTFs. but I don’t believe most people will override the settings to perform the equivalent of an *IMMONLY or an *IMMDLY application.

    So if your operator isn’t changing any settings other than the option to turn off the immediate IPL, your management is correct in saying that immediate PTFs are not immediately applied during an option 8 load. And if PTFINSTYP is set to *DLYIPL or *DLYALL, they’re right in saying that your PTFs won’t be applied until the next IPL.

    Also, if the CHGSRVA PTFINSTYP parameter is set to *DLYALL, you will change the default setting for the Automatic IPL parameter on the GO PTF, option 8 screen from a Y (yes) to an N (No). The benefit in doing this is that you can prevent your operator from accidentally automatically IPLing your system after the PTFs are loaded (and feel more comfortable loading PTFs during the day).

    The other thing you can check after the PTFs are loaded is to run GO PTF, Option 5 (Display PTF) and page through your current PTFs. Look under the IPL actions column to see if there are a large number of PTFs where the IPL Action is set to Yes. That will tell you that those PTFs are waiting to be applied.

    –Joe

    Follow Joe Hertvik on His Blog, on Twitter, and on LinkedIn

    Check out Joe’s blog at joehertvik.com, where he focuses on computer administration and news (especially IBM i); vendor, marketing, and tech writing news and materials; and whatever else he come across.

    You can also follow Joe on Twitter @JoeHertvik and on LinkedIn.

    Joe Hertvik is the owner of Hertvik Business Services, a service company that provides written marketing content and presentation services for the computer industry, including white papers, case studies, and other marketing material. Email Joe for a free quote for any upcoming projects. He also runs a data center for two companies outside Chicago. Joe is a contributing editor for IT Jungle and has written the Admin Alert column since 2002.



                         Post this story to del.icio.us
                   Post this story to Digg
        Post this story to Slashdot

    Share this:

    • Reddit
    • Facebook
    • LinkedIn
    • Twitter
    • Email

    Tags:

    Sponsored by
    Maxava

    Migrate IBM i with Confidence

    Tired of costly and risky migrations? Maxava Migrate Live minimizes disruption with seamless transitions. Upgrading to Power10 or cloud hosted system, Maxava has you covered!

    Learn More

    Share this:

    • Reddit
    • Facebook
    • LinkedIn
    • Twitter
    • Email

    Sponsored Links

    Northeast User Groups Conference:  22nd Annual Conference, April 2 - 4, Framingham, MA
    COMMON:  Join us at the 2012 Conference & Expo, May 6 - 9 in Anaheim, CA
    ITJ Bookstore:  Book Blowout! Chip Wars, by Brian W. Kelly, Now 75% Off!

    IT Jungle Store Top Book Picks

    BACK IN STOCK: Easy Steps to Internet Programming for System i: List Price, $49.95

    The iSeries Express Web Implementer's Guide: List Price, $49.95
    The iSeries Pocket Database Guide: List Price, $59
    The iSeries Pocket SQL Guide: List Price, $59
    The iSeries Pocket WebFacing Primer: List Price, $39
    Migrating to WebSphere Express for iSeries: List Price, $49
    Getting Started with WebSphere Express for iSeries: List Price, $49
    The All-Everything Operating System: List Price, $35
    The Best Joomla! Tutorial Ever!: List Price, $19.95

    EXTOL Updates ERP Adapters, Enhances AS2 Software IBM’s Next Generation Platform Prepped For Launch

    Leave a Reply Cancel reply

Volume 12, Number 7 -- March 28, 2012
THIS ISSUE SPONSORED BY:

Help/Systems
PowerTech
IntelliChief

Table of Contents

  • A Couple of RSE Quickies
  • Down with Dependence!
  • Just When Do IBM i PTFs Get Applied, Anyway?

Content archive

  • The Four Hundred
  • Four Hundred Stuff
  • Four Hundred Guru

Recent Posts

  • Public Preview For Watson Code Assistant for i Available Soon
  • COMMON Youth Movement Continues at POWERUp 2025
  • IBM Preserves Memory Investments Across Power10 And Power11
  • Eradani Uses AI For New EDI And API Service
  • Picking Apart IBM’s $150 Billion In US Manufacturing And R&D
  • FAX/400 And CICS For i Are Dead. What Will IBM Kill Next?
  • Fresche Overhauls X-Analysis With Web UI, AI Smarts
  • Is It Time To Add The Rust Programming Language To IBM i?
  • Is IBM Going To Raise Prices On Power10 Expert Care?
  • IBM i PTF Guide, Volume 27, Number 20

Subscribe

To get news from IT Jungle sent to your inbox every week, subscribe to our newsletter.

Pages

  • About Us
  • Contact
  • Contributors
  • Four Hundred Monitor
  • IBM i PTF Guide
  • Media Kit
  • Subscribe

Search

Copyright © 2025 IT Jungle