Many standard configuration i5/OS Ethernet lines have a common problem. If the line loses connectivity for any reason, the controllers and devices attached to that line will go into a recovery pending state (RCYPND), which requires manual intervention to restart communication. I ran into this problem a few weeks ago and found two solutions for resolving the issue and automatically recovering communications after an outage.

What Happened To My Communications Line?

I experienced this issue when my network services people took down our core network switch for maintenance one Sunday morning, killing Ethernet and TCP/IP connectivity for all network users. After several minutes without communications, the controllers and devices connected to our System i Ethernet lines went into recovery pending state (RCYPND), and they were unable to communicate with the outside world. To restore connectivity, we had to reset all the Ethernet lines after the router came back.

The situation baffled us. Why didn't TCP/IP remain active over our comm lines? Other network servers, including Microsoft Exchange, Windows file servers, and some Novell servers, started communicating again when the router was restarted. Why didn't our System i partitions do the same?

The answer resided in a little known i5/OS configuration parameter for Ethernet lines called the Communication Recovery Limits (CMNRCYLMT). You can find this parameter by running this Display Line Description (DSPLIND) command.

DSPLIND LIND(ETHERLINE) OPTION(*TMRRTY)

This command will show you a display that looks something like this:

                           Display Line Description
                                                  10/26/09  20:23:24
Line description . . . . . . . . . :   ETHERLINE
Option . . . . . . . . . . . . . . :   *TMRRTY
Category of line . . . . . . . . . :   *ELAN

Recovery limits:
  Count limit  . . . . . . . . . . :   2
  Time interval  . . . . . . . . . :   5

These parameters specify second level recovery limits for your line. First level limits deal with the line's inactivity timer; second level limits specify what happens when the connection is entirely lost. The Count Limit parameter specifies how many attempts the line will make to recover connectivity during the number of minutes listed in the Time Interval parameter. The default values for new Ethernet lines are two tries for the count limit and five minutes for the time interval. When a communications failure occurs, your Ethernet line will attempt to re-establish connectivity twice within a five-minute span before going into recovery pending state (RCYPND). The only way to emerge from RCYPND is to manually reset the target line, controller, and device descriptions.

It's important to note that lines configured this way will fail whenever Ethernet communication is cut off for a reasonable period of time (greater than five minutes). I don't know what IBM was thinking when it set up its standard Ethernet configuration this way, but it doesn't work well during a network outage.

How To Fix the Issue

To solve this problem, we ran the following Change Line Desc (Ethernet) (CHGLINETH) command from a 5250 green-screen:

CHGLINETH LIND(ETHERLINE1) CMNRCYLMT(15 1)

CMNRCYLMT changes take affect immediately, so we didn't have to restart the line to enact the change. After running this command, we viewed our new recovery limits by once again running this DSPLIND command:

DSPLIND LIND(ETHERLINE) OPTION(*TMRRTY)

By entering *TMRRTY in the Option (OPTION) parameter, we could view the Ethernet line's recovery limit values on this display:

                           Display Line Description
                                                 10/26/09  20:59:37
Line description . . . . . . . . . :   ETHERLINE
Option . . . . . . . . . . . . . . :   *TMRRTY
Category of line . . . . . . . . . :   *ELAN

Recovery limits:
  Count limit  . . . . . . . . . . :   15
  Time interval  . . . . . . . . . :   1

Two weeks after the change, our network services people took down the core router again to complete their maintenance. This time our Ethernet line waited and re-established its connection without manual intervention after the router came back up.

So What Do These Settings Do?

CMNRCYLMT basically jams your Ethernet line's second level retry configuration and keeps making recovery attempts until it can re-establish connectivity. By changing the Count limit to 15, we told i5/OS to make 15 recovery attempts before giving up. By setting the time interval to one minute, however, it becomes impossible for the system to make 15 recovery attempts in that short a time. When the line can't attempt 15 recovery attempts in a minute, it tries again during the next minute. When that fails, it tries again in the next minute and so on until it successfully re-establishes connectivity. We made this change on an IBM recommendation and it worked great the first time we needed it.

But If That Doesn't Work For You. . .

Interestingly enough, this isn't the only way to prevent Ethernet lines from going into RCYPND state. There is another way to set your CMNRCYLMT parameters so that your line will infinitely try to restore connectivity. Be warned that I haven't tested this configuration yet, so I can't guarantee that it will work. However, this configuration is documented on several Internet sites so if the first technique doesn't work, try this configuration to see if it does the trick.

Run the Change Line Desc (Ethernet) (CHGLINETH) command as follows:

CHGLINETH LIND(ETHERLINE1) CMNRCYLMT(5 0)

Again, CMNRCYLMT changes will immediately take effect. When you run the DSPLIND command, your parameters will now look like this:

                           Display Line Description
                                                 10/26/09  20:59:37
Line description . . . . . . . . . :   ETHERLINE
Option . . . . . . . . . . . . . . :   *TMRRTY
Category of line . . . . . . . . . :   *ELAN

Recovery limits:
  Count limit  . . . . . . . . . . :   5
  Time interval  . . . . . . . . . :   0

When CMNRCYLMT is set up with a zero in the time interval parameter and any number is entered in the count limit parameter, the zero value specifies an infinite retry and recovery interval for your line. This configuration should also allow your lines to reconnect after a network outage or when someone does something stupid, like unplugging your Ethernet cable. Again, I haven't deployed this configuration yet, but there's no reason to think that it won't work. Test before deployment to ensure you won't have any problems.

About Our Testing Environment

Configurations in this article were tested on several System i partitions running i5/OS V5R4. These parameters can also be found on pre-V5R4 i5/OS versions and they are also available in the i 6.1 operating system. Due to time and machine constraints, we did not test the second recovery limit example (where you set CMNRCYLMT to 5, 0) but I believe that technique should work in practice.




                     Post this story to del.icio.us
               Post this story to Digg
    Post this story to Slashdot


Sponsored By
HALCYON SOFTWARE

Learn how automated solutions for IBM i servers can
significantly reduce your operating costs. And understand
how powerful monitoring and automation techniques can
solve your business challenges.

Find out if automated operations solutions for IBM i,
i5/OS makes perfect business sense for your organization.

Learn more


Senior Technical Editor: Ted Holt
Technical Editor: Joe Hertvik
Contributing Technical Editors: Erwin Earley, Brian Kelly, Michael Sansoterra
Publisher and Advertising Director: Jenny Thomas
Advertising Sales Representative: Kim Reed
Contact the Editors: To contact anyone on the IT Jungle Team
Go to our contacts page and send us a message.

Sponsored Links

looksoftware:  Get your FREE copy of the hottest product of the year!
Computer Keyes:  KeyesOverlay rapidly converts standard *SCS printer files into PDF documents
Manta Technologies:  Your complete source for IBM i training


 

IT Jungle Store Top Book Picks

Easy Steps to Internet Programming for AS/400, iSeries, and System i: List Price, $49.95
The iSeries Express Web Implementer's Guide: List Price, $49.95
The System i RPG & RPG IV Tutorial and Lab Exercises: List Price, $59.95
The System i Pocket RPG & RPG IV Guide: List Price, $69.95
The iSeries Pocket Database Guide: List Price, $59.00
The iSeries Pocket SQL Guide: List Price, $59.00
The iSeries Pocket Query Guide: List Price, $49.00
The iSeries Pocket WebFacing Primer: List Price, $39.00
Migrating to WebSphere Express for iSeries: List Price, $49.00
Getting Started With WebSphere Development Studio Client for iSeries: List Price, $89.00
Getting Started with WebSphere Express for iSeries: List Price, $49.00
Can the AS/400 Survive IBM?: List Price, $49.00
Chip Wars: List Price, $29.95


 
The Four Hundred
A Chat with Ross Mauri, Power Systems GM

IBM Slashes Prices on Power Core Activations

JDE EnterpriseOne Costs Less on i OS Than Windows or Linux, ITG Says

Mad Dog 21/21: Can Mashups Save the Advanced Economies?

Soltis Says iManifest Needed to Promote IBM i

Four Hundred Stuff
Open Text to Support new Windows 7 Features in Host Emulators

Halcyon Delivers ERP-Specific Monitoring in Systems Operations Suite 3.0

Healy Launches iPDF Server to Ease Spool File Distribution

mrc Goes Fully Graphical with Development Tool Interface

Inovis Boosts Productivity for Green-Screen Customers

Four Hundred Monitor
Four Hundred Monitor's
Full iSeries Events Calendar

System i PTF Guide
October 31, 2009: Volume 11, Number 44

October 24, 2009: Volume 11, Number 43

October 17, 2009: Volume 11, Number 42

October 10, 2009: Volume 11, Number 41

October 3, 2009: Volume 11, Number 40

September 26, 2009: Volume 11, Number 39

September 19, 2009: Volume 11, Number 38

TPM at The Register
Unisys takes Secure Cloud private

Ruiz out as Global Foundries chairman

Quanta opens servers to 100-core Tilera

IBM facelifts i/OS for midrange gear

Cisco and EMC in joint venture blitz

Moffat leaves IBM after insider trading arrest

Cray has ups and downs in Q3

Sun aims for sky, shoots self in foot

VMware Workstation plays lucky 7

Super Micro serves up not-bad quarter

Unisys squeezes profits from revenue decline in Q3

Asustek opens curtain on desktop 'supercomputer'

THIS ISSUE SPONSORED BY:

Help/Systems
WorksRight Software
Halcyon Software


Printer Friendly Version


TABLE OF CONTENTS
Enhancing CGIDEV2

A Quick-and-Easy Way to Convert Case in RPG Programs

Admin Alert: Keeping i5/OS Ethernet Lines Connected

Four Hundred Guru

BACK ISSUES




 
Subscription Information:
You can unsubscribe, change your email address, or sign up for any of IT Jungle's free e-newsletters through our Web site at http://www.itjungle.com/sub/subscribe.html.

Copyright © 1996-2009 Guild Companies, Inc. All Rights Reserved.
Guild Companies, Inc., 50 Park Terrace East, Suite 8F, New York, NY 10034

Privacy Statement